logo

Fire Suppression Agent System for Kitchen for Restaurant Fire Protection

1 set
MOQ
สามารถต่อรองได้
ราคา
Fire Suppression Agent System for Kitchen for Restaurant Fire Protection
คุณสมบัติ คลังภาพ รายละเอียดสินค้า ขออ้าง
คุณสมบัติ
ข้อมูลจำเพาะ
Maximum working pressure of the device: 1Mpa
Operating temperature: 0-50 ℃
Drive gas name:: Nitrogen
Filling pressure of driving bottle: 6Mpa
Fire extinguishing agent name: Edible oil specific fire extinguishing agent
Reagent filling capacity: 12L (single bottle group)/12L*2 (double bottle group)
Effective spraying time: ≥ 30s
Shelf life of the drug: 3 years
Temperature sensor nominal operating temperature: 183 ℃
Extinguishing type: Edible oil fires
ข้อมูลพื้นฐาน
Place of Origin: China
ชื่อแบรนด์: Air Giant
ได้รับการรับรอง: CAL,CMA,CNAS,ILAC-MRA,CCC
Model Number: CMJS10-1-AG, CMJS18-2-AG
การชำระเงิน
Packaging Details: Plywood outer box with bubble bag or paper
Delivery Time: 10-15 working days
Payment Terms: L/C,D/P,T/T,Western Union,Paypal,Credit card
Supply Ability: 1000 sets per month
รายละเอียดสินค้า

Fire Suppression Agent System For Kitchen For Restaurant Fire Protection


*** Description of Kitchen Fire Suprresion System


Activation Method:

1. Automatic Activation Method:

1.1 Thermal Detection: When a fire occurs in the kitchen oil pot, the heat generated by the flames will cause the temperature inside the hood to rise. When the temperature reaches the preset thermal threshold of the fire suppression system (usually 183°C to 185°C), the thermal detector will automatically disconnect, triggering the fire suppression system to activate automatically.

1.2 Release of Fire Extinguishing Agent: Once the fire suppression system is activated, it will release fire extinguishing agents (such as dry powder, water-based agents, etc.) through atomizing nozzles, spraying them onto the oil pot and inside the hood. These agents will either chemically react with the burning oil or physically isolate it, forming a covering layer to cut off the air supply and extinguish the flames.

1.3 Cooling Down: After the fire suppression system sprays the extinguishing agent, it typically activates a water flow valve automatically, spraying water onto the oil pot and exhaust hood to cool them down and prevent re-ignition. The cooling water is sprayed for about two minutes before the system automatically shuts off the water.

 

2. Manual Activation Method

2.1 Fire Detection: In the early stages of a fire or if the automatic activation system fails, on-site personnel can manually activate the fire suppression system.

2.2 Operating the Manual Activation Device: Follow the instructions on the device to remove the safety pin, pull out the ring, or press the button, causing the drive valve to activate and release the fire extinguishing agent from the high-pressure cylinder.

2.3 Observing the Extinguishing Effect: After manually activating the fire suppression system, observe whether the fire source is completely extinguished and take necessary follow-up measures.

 

3. Mechanical Emergency Activation Method

3.1 Confirming Automatic and Manual Activation Failure: When both automatic and manual activation methods fail to start the device normally, the mechanical emergency activation method can be used.

3.2 Operating the Mechanical Drive Valve: Manually operate the drive valve handle to open the mechanical drive valve, releasing the fire extinguishing agent to extinguish the fire.


*** Components of Kitchen Fire Suprresion System


Fire Suppression Agent System for Kitchen for Restaurant Fire Protection 0


1

Main Cabinet

2

Agent Storage Cylinder

3

Air Inlet Assembly I

4

Air Inlet Assembly II

5

Bearing Box Wheel

6

Thermal Fusible Metal Cable Release Device

7

Nozzle

8

Manual Switch Button

9

Fuel Valve

10

Driving Cylinder Assembly

11

Spanner

12

Tension Spring

13

Mechanical Actuator Assembly

14

Relief Pump Support Assembly

15

High-Pressure Output Pipe Assembly

16

Check Valve

17

Agent Delivery Pipe

18

Conduit

19

Steel Rope

20

Junction Box

21

Water Inlet Pipe

22

Control Panel

 

 

 




*** Working principle of kitchen Fire Suprresion System

                                

The working principle of kitchen fire suppression typically involves three key mechanisms: 

Oxygen Deprivation (Smothering):
Kitchen fires, especially grease or oil fires (Class F), require oxygen to sustain combustion. Fire extinguishers or suppression systems release agents (e.g., wet chemicals, foam, or carbon dioxide) to displace oxygen around the flames. For example, a fire blanket physically blocks oxygen, while CO₂ gas forms an inert layer over burning oil.

Temperature Reduction (Cooling):
Agents like water (in automatic sprinklers) or wet chemical solutions absorb heat energy, lowering the fuel temperature below its ignition point. Water mist systems are particularly effective as they rapidly cool flames and surrounding surfaces without spreading grease.

Chemical Chain Reaction Interruption:
Dry chemical extinguishers (e.g., ABC powder) or specialized wet chemicals disrupt the combustion process at a molecular level. For grease fires, wet agents (potassium acetate/citrate) create a soap-like layer (saponification) that seals the fuel surface, preventing re-ignition.

 


*** Advantage of Kitchen Fire Suprresion System

-- Rapid Response

-- Automated Operation

-- Effective Cooling and Re-ignition Prevention

-- Environmentally Friendly and Safe

-- Wide Applicability

-- Self-Diagnostic Function



*** Application of Kitchen Fire Suprresion System


Kitchen Equipment Fire Suppression Device is mainly used at the following site: hotel, restaurant kitchen, the catering center of the stadium, large/medium/small restaurant, fast food restaurant, the catering center of the airport, the kitchen of the office and hospital, large office building restaurant, the kitchen of industrial and mining enterprises, college canteen and so on.

 Fire Suppression Agent System for Kitchen for Restaurant Fire Protection 1


*** Packages of Kitchen Fire Suprresion System


We pack products with first polyfoam and then the wooden cases. Once products are too big or customers require a pallet for products, we will make products a pallet. The following pictures are the common packing of products:


Fire Suppression Agent System for Kitchen for Restaurant Fire Protection 2




แนะนำผลิตภัณฑ์
ติดต่อกับพวกเรา
ผู้ติดต่อ : Mr. Missaya Lu
โทร : +86 188 1945 1181
อักขระที่เหลืออยู่(20/3000)